The Knowledge Centre provides CHBA members with access to information and resources. It is a growing resource that is currently focused on updating members about national building code information. Please note that this information is a benefit of your membership, and should not be shared beyond your company/organization.

You can browse the items below, filter by category, or enter search terms in the "What are you looking for" box below.

This information is provided by CHBA for informational purposes only and cannot be used as an official or authoritative document.

Alterations to Existing Buildings

Alterations to Existing Buildings

TECH - Essentials

Updates in the 2025 Codes

How the 2025 National Code Applies to Alterations to Existing Buildings (PDF)

Canada’s aging building stock presents both a challenge and an opportunity. On one hand, inconsistent local renovation rules across Canada create unnecessary complexity and cost challenges for renovators. On the other hand, a clear national framework would present a major opportunity to gradually improve the energy efficiency for 14 million existing homes, rather than having ambitious new energy codes apply to a few hundred thousand new builds every year. Nearly half of Canadian homes were built before 1980, making them less energy-efficient and potentially more climate-vulnerable, and renovations for all kinds of reasons already outpace new construction economically, generating over $122 billion in 2025 and supporting 692,500 jobs.

To address the challenge and capitalize on the opportunity, the 2025 National Building Code (NBC) introduces a new Part 10 that establishes a clear and uniform framework for renovations focusing – for now – entirely on energy efficiency.

Key Principles Used for the 2025 Renovation Code

The code requirements are based on principles that renovators already recognize. Instead of forcing older buildings to meet today’s new‑build standards, the approach is to gradually improve their performance in a cost‑effective and technically sound way, taking advantage of opportunities when renovation work is already happening. Energy efficiency upgrades are meant to be done using the home-as-a-system approach, so renovations meant as improvements do not create moisture, durability, fire safety, or indoor air quality problems. Requirements are intended to match the scope of the work and be realistic to apply, so renovations stay affordable and practical and owners are encouraged to proceed with energy upgrades rather than abandon the project.

Above all, the framework relies on flexibility to deal with existing conditions, technical limits, and cost, and to keep renovations within the regulated system rather than pushing them underground.

When Do the Requirements Apply?

If adopted by the province in which the project is located, the 2025 requirements would apply only to voluntary alterations to a building that is more than five years old and only if the alteration affects a component or assembly that affects a home’s energy efficiency (e.g. exterior walls, furnace, etc.).

Routine maintenance, repair and like-for-like replacements are exempt, ensuring that minor work isn’t subject to full code compliance. The rules do not apply to maintenance or repair work, heritage buildings, or additions, since additions are treated as new construction under other code provisions.

What is actually required

The table below describes the building elements that the new code articles deal with and where requirements can be found. It also summarizes what is required. If work is being done on a home (older than 5 years) and the work falls within the scope of one of these technical areas, renovators would have to comply with the minimum requirements in Part 10 for that specific element:

10.9.36.4
Above‑Ground Opaque Building Assemblies
(e.g., walls and attics)

When insulation is added or upgraded as part of a renovation, the thermal performance of walls, roofs, and similar assemblies must be improved toward current code levels (base code 9.36., tier 1) where practical. The code recognizes physical and construction limitations and requires improvement only to the extent reasonably possible.

10.9.36.5
Fenestration, Doors and Skylights

When windows, doors, or skylights are replaced, the new components must meet current minimum energy performance levels or perform at least as well as the existing ones. The interface between the opening and the surrounding wall must also be sealed to maintain air barrier continuity. Routine maintenance or minor repairs are not captured.

10.9.36.6
Assemblies Below‑Grade or in Contact with the Ground 
(e.g. foundation walls)

Where below‑grade walls, slabs, or floors are altered, and insulation is added, thermal performance must be improved toward current requirements (base code 9.36., tier 1) where feasible. The code recognizes physical and construction limitations and requires improvement only to the extent reasonably possible.

10.9.36.7
Airtightness

If renovation work disrupts the air barrier, or if no continuous air barrier exists within the scope of work, the affected areas must be repaired, upgraded or restored to create air barrier continuity. Or overall airtightness must be demonstrated through testing. The intent is to reduce air leakage without creating moisture, ventilation, or indoor air quality problems.

10.9.36.8
HVAC Systems

When HVAC equipment is replaced or upgraded, the new equipment must meet current minimum efficiency levels. Newly installed ducts and plenums must be sealed, and accessible existing ductwork should be sealed where practical. Creating new conditioned space can trigger ventilation and heating requirements, unless existing systems can adequately serve the space.

10.9.36.9
Service Water Heating Systems

When service water heating equipment is replaced, it must meet current minimum efficiency standards. New or accessible hot water piping must be insulated. Routine maintenance and repair are excluded, and the requirements generally align with equipment already regulated at the federal level.

Important notes on the limits of the new Part 10

Avoiding Scope Creep – Specific code wording was chosen to help avoid scope creep and driving renovations into the underground economy, which states, “the provisions of Part 10 are not intended to require building owners to undertake work beyond the planned extent of an alteration.”

To the Extent Possible – Additionally, the code uses the term “to the extent possible” to provide flexibility for renovators when encountering unique situations or surprises. The Notes to the code explain that “to the extent possible” may – in some cases – mean “may not be possible at all.” One example mentioned in the notes is where a basement stairwell is located against an existing foundation wall, preventing ‘practical’ ways of insulating the wall, because in this case, Part 9 requirements may not permit the addition of exterior insulation and because reconstructing or relocating the stairwell might require significant effort and cost. The concept of the phrase “To the extent possible” is intended to encourage increasing energy efficiency as much as possible within existing limitations. It is important to understand that there will be instances where upgrading, for example, the installation of additional insulation, will not be possible and that this is an acceptable outcome for specific locations.